%2 command on line %1 of the CONFIG.SYS file. Line %1
is ignored.
E"%3" was found where "%4" was expected
in the %2 command on line %1 of the CONFIG.SYS file.
Line %1 is ignored.
EThe system cannot accept the option selected.
EThe system cannot accept the combination
of parameters entered.
EThe system cannot print the file
to the device specified.
EThe spooler is not running.
EDOS mode cannot accept the /C or /T parameter.
E%1 file not found.
IIBM Personal Computer
Fixed Disk Setup Program Version 1.20
IFDISK options
Choose one of the following:
1. Create an IBM Operating System/2 partition
or a logical drive
2. Change the active partition
3. Delete an IBM Operating System/2 partition
or a logical drive
4. Display the partition data
Press Enter to continue or
Esc to return to IBM Operating System/2 I5. Select the other fixed disk drive
PEnter choice: IThe partition cannot be made active.
IThe current primary partition is %1.
IPartition %1 is now active.
IThere are no partitions to make active.
IPartition %1 is already active.
PEnter the number of the partition you
want to make active................: IChange the active partition.
IThe primary IBM Operating System/2 partition is created.
IThere is not enough space for %1 cylinders.
IThere is not enough space for a %1 cylinder partition
starting at cylinder %2.
INo space is available to create an
IBM Operating System/2 partition.
IThe primary IBM Operating System/2 partition already exists.
PEnter partition size............: IThe maximum capacity of the fixed disk is %1 cylinders.
PEnter starting cylinder number..: ICreate an IBM Operating System/2 partition
PDo you want to create an active IBM Operating System/2
partition of the maximum size (Y/N)..........? IThe Primary IBM Operating System/2 Partition is deleted.
IThere is no primary IBM Operating System/2 Partition to delete.
PWarning! Data in the Primary IBM Operating System/2 partition
will be lost. Are you sure you want to continue.......? IDelete IBM Operating System/2 Partition
IMaximum capacity of the fixed disk is %1 cylinders.
INo partitions are defined. IPartition Status Type Start End Size
IDisplay partition information
P%1 is not a correct choice. Enter a correct choice.
P%1 is not a correct choice. Enter Y or N
INo fixed disks are present.
IAn error occurred when reading data from the fixed disk.
IAn error occurred when writing data to the fixed disk.
Run the Hardware Diagnostics program diskette.
IThe current fixed disk drive is: %1
PPress Esc to return to the FDISK Options. IThe fixed disk has been updated. The system should
now be restarted. Press Ctrl+Alt+Del.
IThe fixed disk is in use.
No partitions can be created or deleted.
EThe PATCH parameters are incorrect.
EThe data specified in the patch
control file was incomplete.
IPatching %1
PDo you want to continue patching %1? (Y/N) INo patches applied.
IPatches entered for %1
PDo you want these patches applied to %1? (Y/N) IPatches applied to %1
INo patches applied to %1
IEnd of file is at %1
PEnter the hexadecimal offset of patch: EThe offset is beyond the end of the file.
EThe number of patches exceeds the
limit of PATCH.
WNo file specified to patch in
patch instruction file %1
EA %1 command was found without a %2 command.
E%1 is not a valid offset for %2.
E%1 is not a correct hexadecimal string for %2.
EOffset %1 for %2 is too close
or beyond offset %3 (end of file) to verify %4
bytes.
EThe verification failed for %1.
EOffset %1 for %2 is
beyond offset %3 (end of file).
EPATCH detected an unknown
patch instruction file command: %1
EPATCH cannot open %1 to
append to %2.
ENo patches were specified for %1.
EThe MODE parameters are incorrect.
ICharacters per line has been set.
ILines per inch has been set.
IInfinite retry has been set.
I-- More --IInfinite retry has been reset
IMODE is unable to set the ReadBack function for the diskette.
The process has ended.
IAsynchronous Communications mode has been set.
IMODE DSKT VER=%1
IThe parallel printer cannot be
redirected to a communication device. Use
the SPOOL utility to redirect the output.
PInsert a diskette in drive A and press enter to continue or
press CTRL+Break to cancel the MODE command.
EThe MODE parameter %1 is not supported in DOS mode.
EThe COM port specified is not installed.
IThe MODE diskette ReadBack command has been successfully completed.
EThe MODE parameter %1 is not correct.
EThe MODE parameter DISPLAY is missing.
EThe MODE parameter %1 is not correct.
EThe MODE parameter %1 is not correct.
EThe MODE parameter %1 is not correct.
EThe MODE parameter %1 is not correct for the type of video
device specified.
Files will be restored from drive %1:
Insert backup diskette %1 in drive %2:
Press Enter when ready.
Warning! The diskette is out of sequence.
Replace the diskette or press Enter to continue.
Warning! File %1 is a read-only file.
Replace the file (Y/N)?
Warning! File %1 was changed after the backup.
Replace the file (Y/N)?
Operating system files are restored.
The target disk may not be usable.
The files were backed up on %1.
The source and target drives entered are the same.
The number of parameters entered is incorrect.
No files were found to restore.
The last file listed was not restored.
The source diskette does not contain backup files.
EThe system cannot restore a file in an
incorrect order.
The system cannot restore the file.
PDiskette %1
Insert the RESTORE target diskette in drive %1.
Press Enter when ready.
EThe system cannot write to the BACKUP
log file. Press Enter to continue, or press
Ctrl+Break to cancel.
EThe drive letter must be specified
for the BACKUP command.
ENo source drive was specified.
ENo target drive was specified.
EThe source and target drives entered are the same.
EThe system cannot run the FORMAT command.
IKEYS is on.
IKEYS is off.
EThe system cannot find the drive specified.
EThe system cannot find the FORMAT utility.
EThe system cannot open the logfile.
EThe BACKUP command cannot format
nonremovable drive %1.
IThe last backup target diskette
was not inserted.
IThe BACKUP command is logging to file %1.
IWarning! The files in the root directory
of target drive %1: will be erased.
Press Enter to continue or Ctrl+Break to cancel.
IWarning! The files in the \BACKUP directory
of target drive %1: will be erased.
Press Enter to continue or Ctrl+Break to cancel.
IThe files are being backed up to drive %1.
PDiskette number %1
IThe system cannot find any files to back up.
PInsert a backup source diskette in %1:
Press Enter to continue or Ctrl+Break to cancel.
PInsert backup diskette %1 in drive %2:
EThe file cannot be backed up at this time.
PInsert the last backup diskette in drive %1:
Press Enter to continue or Ctrl+Break to cancel.
EThe target disk cannot be used
to back up files.
IThe last file was not backed up
because the target fixed disk is full.
ITarget fixed disk %1: is full.
EThe system cannot create the directory.
EThe pathname is too long.
P (Y/N)? ?
ISource files are being read...
I%1 file or directory cannot be found.
P%1 specifies the directory or filename.
Does %1 specify a directory (Y/N)? EThe system cannot copy to a
subdirectory belonging to the source directory.
EXCOPY cannot be performed.
IANSI extended screen and
keyboard control is on.
IANSI extended screen and
keyboard control is off.
IThe system cannot load the startup file system which
is needed to start the system. The information for the startup
file system is incorrect. Reinstall your system.
IThe system cannot initialize the startup file system
which is needed to start the system. Reinstall your system.
EThe system cannot find the file "%3" specified
in the %2 command on line %1 of the CONFIG.SYS file.
Line %1 is ignored.
EThe file "%3" specified in the %2 command
on line %1 of the CONFIG.SYS file does not contain a
valid device driver. Line %1 is ignored.
IThe information needed to IPL the system is not
acceptable.
IBM Operating System/2 Version 1.20
(C) Copyright IBM Corp. 1981, 1989. All rights reserved.
(C) Copyright Microsoft Corp. 1981, 1989.
IThe system cannot load the dynamic link library %1
which is needed to start the system.
Install the dynamic link library in the root directory of
the startup drive or in the directory specified in the
LIBPATH command in the CONFIG.SYS file.
IThe system cannot find the entry point %2 in
dynamic link library %1 which is needed to start the system.
Install the correct dynamic link library in the root
directory of the startup drive or in the directory
specified in the LIBPATH command in the CONFIG.SYS file.
IThe system cannot open the CON: file, which is
needed to start the system.
IThe handle for the CON: file is not zero.
Press Enter to continue.
EThe system does not have enough storage for the
DISKCACHE buffers.
EThe system does not have enough storage to enable
disk caching.
EThe code page "%1" is not acceptable for the
display.
EThe code page combination "%1" is not acceptable
for the keyboard.
EThe country information file "%1" is incorrect.
IThe system has assumed code page %1.
ICode page switching is not available.
EThe system has detected an error when starting.
EThe KEYB command cannot find the translation
table file for the keyboard in the path specified by
the DEVINFO= statement of the CONFIG.SYS file.
EThe KEYB command has detected an error reading
the translation table file for the keyboard.
EA system error has occurred.
PCode page %1 is not available for the requested country keyboard.
Do you want to load the translation table for the default code page (Y/N)?
EThe Default Translate Table for the country code entered was
not found.
IThe system cannot reload the default table
because it is already loaded.
EThe system cannot open the keyboard.
EThe system cannot accept the keyboard
type specified.
EThe system has detected an error while
loading the translate table.
IThe translation table for code page %1 has been loaded.
EThe system cannot accept the parameter %1
EThe system is unable to get or
change the code page for this process.
IActive code page: %1
Prepared system code pages: %2
ECode page %1 is not prepared for system.
INo code page support is available on the system.
ICode page %1 is not prepared for device %2.
EThe system cannot accept the START command
parameter %1
EThere are no currently printing files in the print
queue.
PThere are too many printer queues associated with the device.
Your job request is queued to print and cannot be cancelled.
PThere are no printer queues associated with the device.
Your job request is not queued to print and cannot be cancelled.
EThe Presentation Manager spooler is not installed.
EThe Presentation Manager print device
specified is not installed. (not ready)
EThe PRINT command has detected an unexpected
Presentation Manager error.
ESPOOL cannot load the font switching file.
EOne or more code page values in the
CODEPAGE= statement of the CONFIG.SYS file are
incompatible with the specified printer.
EAn error occurred while attempting to open
the font file for the specified printer.
EAn error occurred while reading the font
file for the specified printer.
EThe font file specified in a printer's
DEVINFO= statement in the CONFIG.SYS file is not
compatible with the printer type.
EThe system does not have enough storage to do
code page switching.
EThe font file specified in the DEVINFO=
statement in the CONFIG.SYS file is not correct.
EFont switching may not be available
because of an error in the system.
EThe system detected too many code page
specifications in the the DEVINFO= statement in the
CONFIG.SYS file.
ESome of the code page specifications
will not be available.
EThe Presentation Manager input device specified by
the spool command is busy and cannot be used by the spooler.
EThe Presentation Manager output device specified by
the spool command is busy and cannot be used by the spooler.
EAn unexpected error was detected from the
Presentation Manager.
PThe spool directory parameter is no longer supported.
Spool will ignore the parameter and continue processing.
EThe system cannot find the file %1.
EThe process tried to write to a nonexistent pipe.
EThe system cannot start the session in the foreground.
IA non-recoverable error occurred.
The process ended.
EThe system detected a divide by zero error.
EThe process has stopped. The software
diagnostic code (trap number) is %1.
EThe process ended when it tried to use
a non-existent math processor.
The external process was cancelled by a Ctrl+Break or another process.
E"%1" is not a recognized OS/2 device.
EThe batch file cannot be found.
IThe file or directory %1 has an incorrect Extended Attribute chain.
EInsufficient memory is available to examine Extended Attributes
chains. Processing continues.
I%1 bytes in Extended Attributes.
IAn error was found in the Extended Attributes for a file
or directory. The error will be ignored unless you convert the
Extended Attributes to files. Do you want to convert these Extended
Attributes chains to files (Y/N)? IAn error was found in the Extended Attributes for a file or
directory. Do you want to display these Extended Attributes chains as
files (Y/N)? IThe file/directory was renamed to %1 its Extended Attributes
are in %2.
IThe first Extended Attributes cluster number of %1 is incorrect.
The entry has been truncated.
IThe file or directory was renamed to %1, its Extended Attributes
are in %2.
EThe system cannot locate the file &flname..
The file is not in the directory
that contains the Program Selector
(SHELL11F.EXE).
Write down these steps:
1. Copy the file listed above into the directory
that contains the Program Selector,
or reinstall the system.
2. Restart the system.
Press any key to continue. Then do steps 1 and 2.
EThe system does not have enough
storage to process the command.
There is not enough storage available.
Make more storage available. For example,
decrease the value specified for the RMSIZE=,
BUFFERS=, or TRACEBUF= statement in the
CONFIG.SYS file. Then restart the system.
EThe system cannot process this request.
A non-recoverable error occurred.
Try to save all your programs and data.
Then restart the system.
EThe system cannot start the selected
program.
The maximum number of programs are currently running.
End a running program. Then start another program.
EThe system cannot set the mouse
button assignments.
The mouse may not be installed properly.
Check that the mouse software is properly installed.
Then restart the system.
EThe system has detected an
unacceptable executable format in the file.
The program is either formatted
incorrectly or is an incorrect
version of IBM Operating System/2.
Run the program from DOS mode.
PDo you want to use the maximum
size for an IBM Operating System/2 partition (Y/N) .....? PChoose one of the following:
1. Create primary IBM Operating System/2 partition
2. Create extended IBM Operating System/2 partition
P 3. Create logical drive(s) in
the extended IBM Operating System/2 partition
PCreate Primary IBM Operating System/2 Partition
PCreate Extended IBM Operating System/2 Partition
PCreate Logical Drive(s)
IExtended IBM Operating System/2 partition created.
IDisk volume %1 created
PChoose one of the following:
1. Delete the Primary IBM Operating System/2 partition
2. Delete the Extended IBM Operating System/2 partition
P 3. Delete the logical drive(s) in
the Extended IBM Operating System/2 Partition
PDelete the Primary IBM Operating System/2 Partition
PDelete the Extended IBM Operating System/2 Partition
PDelete the Logical Drive
IAll the logical drives have been
deleted in the Extended IBM Operating System/2 partition.
IThe extended IBM Operating System/2 partition was deleted.
IThe drive has been deleted.
IWarning! The partition marked is
not a startup partition.
IWarning! Data in the logical drive will be lost.
What drive do you want to delete.........? IWarning! Data in the Extended IBM Operating
System/2 partition will be lost. Do you want
to continue.......................? PAre you sure......................? PEnter the size of the logical drive........: PThe Extended IBM Operating System/2 partition
contains logical drives. Do you want to display
the logical drive information.........? PPress Esc to return to IBM Operating System/2.
PThe total partition size is %1 cylinders.
The maximum contiguous space available for
the logical drive is %2 cylinders.
IThe total partition size is %1 cylinders.
ICurrent Fixed Disk Drive: %1
IThe drive letters have been changed or deleted.
IThe only startup partition on Drive 1
is already marked active.
IAll available space in the Extended IBM Operating
System/2 partition is assigned to logical drives.
INo startup partitions exist.
IOnly partitions on Drive 1 can be
made active.
IThe maximum number of logical IBM Operating
System/2 drives are installed.
IThe primary IBM Operating System/2 partition on drive 1
cannot be deleted when an Extended partition exists.
IThe maximum available space for the partition
is %1 cylinders.
IDrive Start End Size
I%1 %2 %3 %4
I%1 %2 %3 %4 %5 %6 %7
IAn Extended IBM Operating System/2 partition
already exists.
IAn Extended IBM Operating System/2 partition
does not exist.
IA partition or logical drive cannot be less than 32K bytes.
INo logical drives are defined.
IThe requested logical drive size exceeds
the maximum space available.
IThe requested partition size exceeds the
the maximum space available.
IThere are no partitions to delete.
IAn Extended IBM Operating System/2 partition cannot
be created without a Primary partition on Disk 1.
PAn Extended IBM Operating System/2 partition cannot
be deleted while logical drives exist. IA zero cannot be specified as the number of
cylinders.
IThe drive %1 was previously deleted.
IAn internal error occurred in FDISK.
INo Parameters are allowed with FDISK.
EThe system cannot start another IBM
Operating System/2 mode session.
I%1 was installed.
ICOM device driver Version 1.20 is being installed.
EThe query status function for COM port
is not available in DOS mode.
WThe infinite retry option, P, is not valid in
the OS/2 session. It has been ignored.
PInsert the Device Support diskette in drive A
and press Enter when ready. EThe diskette in drive A does not contain the profile
control files or is defective.
PThe Device Support diskette is installed.
Remove the diskette from drive A.
PInstallation of the Device Support diskette
is not complete. To continue:
I%1 file(s) moved.
PInsert the OS/2 Installation Diskette in drive A;
then press Enter. EThe diskette in drive A contains a defective profile
control file.
PPress simultaneously the CTRL, ALT, DEL keys to
restart the system.
IThe system detected an internal processing
error at location %1.
The system is stopped.
IThe system detected a user error at location %1.
EThe file "%3" specified in the %2 command on
line %1 of the CONFIG.SYS file does not contain a valid
program. Line %1 is ignored.
EThe application called the system with the
interrupts off. The application has ended.
Arguments used in system call (high to low):
EThe file "%1" does not contain a valid program.
IThe system detected a general protection
fault (trap D) in a system call.
Arguments used in system call (high to low):
EA DOS mode
program changed an interrupt vector that
is owned by the system. The program was ended.
EThe system does not have enough storage
to reload a code or data segment.
EA program caused a divide error.
The program was stopped.
EA program caused a single-step error.
The program was ended.
IThe system detected a hardware memory error.
Run the diagnostics supplied with your system to
determine the cause of the problem.
EA program caused a breakpoint error.
The program was ended.
EA program caused an overflow error.
The program was ended.
EA program caused a bound range error.
The program was ended.
EA program started an invalid instruction.
The program was ended.
EA program started a numeric coprocessor
instruction, but there is no coprocessor present. The program
was ended.
EA system error occurred.
EA program ran a numeric coprocessor instruction
that attempted to reference storage past the end of a
storage segment. The program was ended.
EA system error occurred.
EA program tried to reference a storage segment that
is not in storage. The program was ended.
EA program attempted to reference storage outside the
limits of a stack segment. The program was ended.
EA program caused a protection violation.
IThe system detected a nonmaskable interrupt.
IThe system detected a hardware memory error
on the system board.
The system stopped.
Run the diagnostics supplied with your system to
determine the cause of the problem.
IThe system detected a hardware memory error
on an option card.
The system stopped.
Run the diagnostics supplied with your system to
determine the cause of the problem.
IThe system detected a timeout on the DMA channel
of the hardware.
The system stopped.
Run the diagnostics supplied with your system to
determine the cause of the problem.
IThe system detected a timeout by the watchdog
timer on the system board.
The system stopped.
Run the diagnostics supplied with your system to
determine the cause of the problem.
EA program ran a numeric coprocessor
instruction with an incorrect operand. The program was
ended. The error occurred at address %1.
EA program started a numeric coprocessor
instruction with a denormalized operand. The program was
ended. The error occurred at address %1.
EA program instruction caused the numeric coprocessor
to try to divide a number by zero. The program was
ended. The error occurred at address %1.
EA program ran a numeric coprocessor
instruction that generated a result that exceeds the
capacity of the coprocessor. The program was
ended. The error occurred at address %1.
EA program ran a numeric coprocessor
instruction that generated a result that is too small
for the coprocessor. The program was
ended. The error occurred at address %1.
EA program ran a numeric coprocessor
instruction that caused a rounding error. The program